Veuillez sélectionner l´option `Se souvenir de moi sur cet ordinateur` si vous souhaitez vous connecter automatiquement sur cet ordinateur la prochaine fois. Votre compte restera actif pendant 45 jours. Il est conseillé d´utiliser cette option uniquement si vous vous connectez depuis votre ordinateur personnel et non depuis un ordinateur public.
Voir plus de produits liés à:
EU PLUG.
Salicru´s SLC TWIN PRO2 series UPS systems feature on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.
The systems come in a tower format and are available in power ratings of 4, 5, 6, 8, 10, 15 and 20 kVA.
The Salicru SLC TWIN PRO2´s output voltage is always single-phase, featuring a single-phase input of 4 to 20 kVA and a three-phase input of 8 to 20 kVA.
All devices with single-phase input provide a unitary output power factor (1), the most optimum for systems and environments with high energy needs.
Adaptability is another important feature thanks to the numerous operating modes available:
On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.
The possibilities of control and monitoring are varied:
on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.
(1) Except 15 and 20 kVA I / I models Features:
- On-line double conversion and DSP control technology.
- Output power factor PF=1(1).
- Compact tower format for space saving.
- Active power factor corrector for all input phases.
- Multiple operating modes for better adaptability.
- Equipped for parallel operation as standard, up to 3 devices.
- USB and RS-232 interface for all models as standard.
- Monitoring software for Windows, Linux, Unix and Mac (downloadable).
- Intelligent slot for SNMP/RS-485/optocoupler cards.
- Eco-mode operation for increased efficiency.
- Backup extensions available for all power ratings.
- Frequency conversion function.
- EPO.
- emergency power off.
- Manual and/or automatic programmable battery test.
- SLC Greenergy solution.
- (1) PF=0.9 for devices with mono-phase input 15 and 20 kVA I/I, three-phase input SLC TWIN/3 PRO2 models Specifications:
- UPS topology:
Double-conversion (Online).
- Output power capacity:
4000 VA.
- Output power:
4000 W.
- Input operation voltage (min):
110 V.
- Input operation voltage (max):
276 V.
- Input frequency:
50/60 Hz.
- Output operation voltage (min):
208 V.
- Output operation voltage (max):
240 V.
- Output frequency regulation:
4 Hz.
- Output voltage regulation:
1%.
- Number of input phases:
1.
- Number of output phases:
1.
- Efficiency (On-line mode):
94%.
- Input power factor:
0.99.
- Output power factor:
1.
- Crest factor:
3:1.
- ECO mode:
Yes.
- Emergency Power Off (EPO):
Yes.
- Overload capacity (10 minutes):
110%.
- Overload capacity (1 minute):
130%.
- Output voltage Total Harmonic Distortion (THD):
4%.
- Input current Total Harmonic Distortion (THD):
4%.
- Total Harmonic Distortion (THD) (linear load):
1%.
- Total Harmonic Distortion (THD) (non-linear load):
4%.
- Noise level:
60 dB.
- Surge protection:
Yes.
- Power protection Features:
Under voltage.
- Maximum number of paralleling UPSs:
3.
- Synchronisation with mains:
4 Hz.
- Synchronisation without mains:
0.1 Hz Features:
- Temperature voltage compensation:
Yes.
- Maintenance-free:
Yes Ports & interfaces:
- AC outlet types:
C13 coupler.
- AC outlets quantity:
2 AC outlet(s).
- Number of output IEC jumpers:
2.
- USB port:
Yes.
- USB 2.0 ports quantity:
1.
- Serial interface:
Yes.
- Serial interface type:
RS-232.
- RS-232 ports:
1.
- Parallel ports quantity:
3.
- Emergency Power Off (EPO) connector:
Yes Battery:
- Battery technology:
Lead-Calcium (Pb-Ca).
- Battery recharge time:
7 h.
- Automatic battery test:
Yes.
- Cold start:
Yes.
- Off-mode charging:
Yes Design:
- Form factor:
Tower.
- Cooling type:
Active.
- Built-in fan:
Yes.
- Product colour:
Black.
- LED indicators:
Yes.
- Display:
LCD.
- Safety:
EN 62040-1.
EN 60950-1 Operational conditions:
- Operating temperature (T-T):
0.
- 40 °C.
- Operating relative humidity (H-H):
0.
- 95%.
- Operating altitude:
0.
- 5000 m.
Weight & dimensions:
- Width:
250 mm.
- Depth:
592 mm.
- Height:
576 mm.
- Weight:
81 kg Other Features:
- I/O ports:
Intelligent slot.
- Battery type:
AGM.
- Bypass:
Hybrid, Nill.
Si vous êtes avide de électronique et informatique, vous trouverez sur techinn des milliers de références à ne pas manquer! Si vous souhaitez trouver des références de Onduleur de qualité, n’hésitez pas à faire un tour dans notre catalogue en ligne qui se fera un plaisir de vous satisfaire. Vous y trouverez votre Salicru UPS SLC-4000 Twin Pro2 à prix réduit.
Écrivez un avis sur ce produit et gagnez CoINNs
Laisser un avis sur ce produit
Tradeinn Retail Services, en tant que responsable du traitement, traitera vos données afin de répondre à votre requête ou demande. Vous pouvez accéder, rectifier et supprimer vos données, ainsi qu´exercer d´autres droits en consultant les informations complémentaires et détaillées sur la protection des données dans notre protection des données à caractére personnel.
RETOUR FACILE
EN 30 JOURS
PAIEMENT
100% SÉCURISÉ
SATISFAIT OU
REMBOURSÉ
GARANTIE DU
MEILLEUR PRIX
Produits associés
$64.99
$45.99
$73.99
$17.99